PHO7-Y/D-B 1 hydraulic electric extracorporeal shock wave lithotriptor (B-ultrasound localization)

Unit: SET

Size:

Price:

Main performance and technical instructions

High performance and high-quality discharge telegraphy

Electrode discharge frequency: ≥ 2000 times

Treatment distance 2135cm

Power supply voltage: AC220V (1+1%) 50Hz+1Hz

Working voltage: 3.5KV~6KV, automatically adjustable

Suburban area: radial s7mm, axial s12.5mm

Trigger method: manual, automatic

Technical Parameter

1. Equipment use: To treat urinary tract stones.

2. Shock wave generator:

★ (1) Shock wave source: Large aperture reflection cavity with a diameter of 200mm, excellent focusing performance, and long treatment distance.

(2) It has the function of exchanging hydraulic, electrical, and electromagnetic dual wave sources.

★ (3) High voltage discharge range: 3.5-6KV.

(4) High performance discharge electrode, high-quality brass inner core, discharge frequency ≥ 2000 times.

(5) Peak compressive sound pressure at the focal point: 20Mpa~100Mpa.

(6) Peak expansion sound pressure: 0Mpa~8Mpa.

(7) Shock wave pressure pulse width ≤ 1 μ S.

(8) Shock wave pressure pulse rise time ≤ 0.5 μ S.

★ (9) Focusing body size: radial ± 7mm, axial ± 20mm.

★ (10) The distance between the focus of the pressure pulse and the plane of the pulse generator port is ≥ 135mm.

(11) The shock wave triggering method has manual and automatic modes

3. Shock wave therapy head:

★ (1) The treatment head is suspended above the treatment bed, capable of lifting up and down by 160mm, extending back and forth by 150mm, and rotating laterally by 90 degrees.

★ (2) The hanging treatment head can be extended to rotate from multiple angles, front, back, left, and right, making positioning very easy and flexible.

4. Operating system:

(1) The operation box is hung by the bedside and movable, making it easy for doctors to communicate with patients during operation.

(2) The energy of crushed stones can be adjusted steplessly.

(3) The frequency of gravel discharge can be adjusted.

(4) Equipped with heating control device and overtemperature protection device.

★ 5. Positioning system: A 360 degree B-ultrasound positioning device, where the B-ultrasound probe can move around the focal point from multiple angles.

6. Treatment bed:

(1) The displacement distance of the treatment bed: longitudinal ≥ 110mm, transverse ≥ 130mm.

(2) The minimum displacement is ≤ 1mm in all directions of movement.

(3) The load capacity of the treatment bed is ≥ 135kg.

7. Has passed electromagnetic compatibility testing and meets the requirements. (Provide a copy of the testing report)